General Brushless Motor Wiring Method C
This document introduces the general wiring method C, applicable to the Ø16, Ø36, and Ø42 series of slotted brushless motors.
Connection mode C |
Pin NO. | SIGN AL | I/O | Specification | Remark |
1 | Vcc | IN | DC 12V(Operating range:8.5V-15V) | Red wire , motor power supply |
DC 24V(Operating range:8.5V-24V) |
2 | FG | VOH | OUT | Yello w wire , this is the open collector output (NPN),which can detect the rotation speed using the FG output according to the phase shift |
|
VOL | 0 ~ 5.0V | ||||
Signal current | Min1.5V | ||||
Output pulse | Max 0.6V | ||||
3 | CW&CCW | Input voltage | IN | 1.5V≤U≤5.0V, at5V | White wire, CCW / CW Select |
VIH | 0.6V max | CCW , High=CCW | |||
VIL | 3mA max | CW , Low= CW | |||
4 | GND | IN | 6 pulse,can be customized | Black wire ,Ground | |
5 | PWM | Input voltage | IN | 0 ~ 50V | Blue wire |
VIH | Min 1.5V | Motor stop,High =stop | |||
VIL | Max 0.6V | Motor running low=start | |||
PWM frequency | Advised 20kHz ~ 30kHz | ||||
6 | BRAKE | Input voltage | IN | 0 ~ 5.0V | Green wire |
VIH | Min 1.5V | Motor start ,High=start | |||
VIL | Max 0.6V | Motor stop,low=stop | |||
Note: 1、Vcc and GND can not be used interchangeably. 2、Please switeh CW/CCW after the motor is fully stopped. In order to avoid any damage. 3、How to start the motor: Red wire connect to the positive, black and white wires connect to the GND.If CCW direction: Connect white wire to low level power; If CW direction: Connect both black、 white and orange wires to low level power. |